306A
Plumber
Real exam 125 questions · 88 to pass · 4 hours
Practice questions
739 original questions for this trade. Pick the kind of test.
Or drill one section
- APerforms common occupational skills41 questions
- BPrepares and assembles tube, tubing and pipe94 questions
- CSewers, sewage treatment and DWV352 questions
- DWater service and distribution107 questions
- EFixtures, appliances and water treatment79 questions
- FLow-pressure steam and hydronic systems40 questions
- GSpecialized systems26 questions
Study
Drainage, waste and vent is the heavy block — 32 of 125. Water distribution is next. Steam is on the standard, but some tasks are not on every interprovincial form.
The paper is 125 questions and four hours. Drainage, waste, and vent is 32 of them, and 20 of those 32 are interior DWV. Water service and distribution is 24. Seventy percent is 88 right. There is no penalty for guessing. Spend the hours on venting and water, then hydronics. Low-pressure steam is not on the common-core form.
The National Plumbing Code of Canada 2020 is free to read online from the National Research Council. The code-book drills on this page are written from that book. A miss keeps the article and the sentence, so you can see the exact line you missed. A 2025 model code is published. Use the edition your apprenticeship office names. Ontario amends the model code in the Building Code. The Canadian Electrical Code is a different book, and it is not free.
Know these cold, then prove them in the code drills: trap seal not less than 38 mm, and 50 mm on acid waste. Drainage pipe NPS 3 or smaller slopes at least 1 in 50. Trap arms from Table 2.5.6.3: 1¼ is 1.5 m, 1½ is 1.8 m, 2 is 2.4 m, 3 is 3.6 m, 4 is 9.8 m. The arm must be at least twice the pipe size, and its fall cannot exceed its inside diameter. A water closet vent stays within 1 m vertical and 3 m horizontal. Continuous flow is 31.7 fixture units per litre per second.
APerforms common occupational skills
14 questions, 11 percent
BPrepares and assembles tube, tubing and pipe
13 questions, 10 percent
CSewers, sewage treatment and DWV
32 questions, 26 percent
DWater service and distribution
24 questions, 19 percent
EFixtures, appliances and water treatment
17 questions, 14 percent
FLow-pressure steam and hydronic systems
16 questions, 13 percent
GSpecialized systems
9 questions, 7 percent
Drainage fall
Fall (mm) = length (mm) ÷ slope number
1:50 means divide by 50. 1:100 means divide by 100.
Which slope
3 inch and smaller: 1:50. 4 inch and larger: 1:100.
National Plumbing Code approach. Confirm the edition your province adopted.
Water column
kPa ≈ metres × 9.8
Static head, before pipe friction.
Trap seal
38 mm minimum. 50 mm if it evaporates or takes acid.
Fall of a trap arm cannot exceed its inside diameter.
Trap arm length
1¼: 1.5 m. 1½: 1.8. 2: 2.4. 3: 3.6. 4: 9.8 m.
Also at least two pipe diameters long. 4 inch may slope at 1:100.
Max pressure
550 kPa
Above that, a pressure-reducing valve. A check or a PRV means an expansion tank on the heater.
Linear expansion
Growth = length × ΔT × coefficient
Copper in these drills uses 0.017 mm per metre per °C.
Cylinder volume
V = π × r² × h
Radius is half the inside diameter. 1 m³ = 1 000 L.
Scores
Opening scores.
With your code book
National Plumbing Code of Canada 2020, the free online book. Code search asks for the article. Code calculation asks for the number in that article. A miss keeps the sentence.